0.2 um PES membrane biological agent filtration process lab use 2.5″ capsule filter
To regularly increase the management program by virtue of your rule of “sincerely, good faith and quality are the base of business development”, we extensively absorb the essence of associated solutions internationally, and continuously create new solutions to satisfy the demands of customers for 0.2 um PES membrane biological agent filtration process lab use 2.5″ capsule filter, We have now confident that we can easily offer the premium quality products and solutions at resonable price, good after-sales services into the buyers. And we’re going to produce a dazzling future.
To regularly increase the management program by virtue of your rule of “sincerely, good faith and quality are the base of business development”, we extensively absorb the essence of associated solutions internationally, and continuously create new solutions to satisfy the demands of customers for OEM China high quality PES capsule filter, We also have good cooperation relationships with many good manufacturers so that we can give almost all of auto parts and after-sales service with high quality standard,lower price level and warmly service to meet demands of customers from different fields and different area.
◆ Capsule filters are kind of self contained,ready to use,disposable filters
◆ Made up of polypropylene cage and pleated membrane filter inside by the rmal bonding,free of adhesives,binders and other chemicals
◆ Available with a wide range of connectors and filter medias for options to meet various filtration requirements
◆ Ideal for small batch prefiltration and final filtration of liquids or gas in laboratory
◆ Fully integrity tested before release from manufacture
• Digital inks, paintings
• Small injection and tissue cultures in pharmaceutical industry
• Corrosive liquids/solvents filtration in chemical industry
• Photoresist, acids, etc in electronic industry
• Gas/Air sterile filtration
• Laboratory solutions
| Table : Filter Media and Pore Size available | ||
| Filter Media | TS CODE | Pore Size(um) |
| PES | IPS | 0.10, 0.20, 0.45, 0.65 µm |
| PP | DPP | 0.10, 0.20, 0.45, 1.00, 3.00, 5.00, 10.0 µm |
| PTFE | IPF | 0.10, 0.20, 0.45, 1.00 µm |
| NYLON66 | PNN | 0.10, 0.20, 0.45, 0.65, 1.00 µm |
| PVDF (Hydrophilic) | DHPV | 0.10, 0.20, 0.45, 1.00 µm |
| Materials Of Construction | Filter Media: | PP/PES/PVDF/PTFE/Nylon and other Membranes for Options | ||||
| Support Layers: | Polypropylene | |||||
| Inner core: | Polypropylene | |||||
| Outer Cage, End caps: | Polypropylene | |||||
| Cartridge Dimensions | Outer Diameter | 69mm/60mm | ||||
| Length | Nominal 1.5″, 2.5″, 5″ 10″ | |||||
| Connectors: | MNPT; Hose barb; Sanitary Flange(Tri-Clamp); Compression joint and so on | |||||
| Filtration Area(m2) | 0.045 m2 to 0.44 m2 | |||||
| Operating conditions | Normal Operating Temperature: | Up to 60℃ (140℉) | ||||
| Max.Operating Temperature.: | 80℃ (176℉) at △P≤1.0 bar (14psi) | |||||
| Max. Differential Pressure | 2.4 bar (34.8psi) at 25℃ (77℉). | |||||
| Normal Flow direction: | 4.2 bar (60 psi) at 25℃ (77℉) | |||||
| Reverse flow direction: | 2.1 bar (30psi) at 25℃ (77℉). | |||||
| Sterilization: | Autoclave sterilization 30 minutes, Gamma-irradiation (Need to confirm with Seller) |
|||||
| TYPE | FILTER MEDIA | MICRON | CONNECTIONS | LENGTH | Vent/Drain | |
| K68B – Φ68 (Filtration Area 1200cm2 or 2200cm2 or 4400cm2 for option) | IPS – Polyethersulfone | 0.1um-010 | A- 1 1/2″ Tri-clamp (K68C type only) | 1- 1.5″ (K60 only) | M10 (K68B & K60) | |
| K60 – Φ60 (Filtraion Area 450cm2) | IPP – Polypropylene | 0.2um-020 | B-1/2″ Tri-clamp (K68C type only) | 2 - 2.5″ (K68B&K68C) | 1/8″ Hose Barb (K68C only) | |
| K68C- Φ68(Filtration Area:1200cm2 or 2200cm2 or 4400cm2 for option) | IPF – Polytetrafluoroethylene | 0.45um-045 | C-1/4″MNPT ( K68B&K60 only) | 5- 5″ (K68B&K68C) | ||
| PNN – Nylon | 0.65um-065 | D-1/2″MNPT ( K68B only) | 10- 10″ (K68B&K68C) | |||
| DHPV – PolyvinylideneFluoride | 1um-100 | E- 9/16″ Hose barb (K68B only) | ||||
| CNCA | 5um-500 | F- 1/4″compression joint (K60 only) | ||||
| 10um-1000 | G- 1/4″ Hose Barb (K68B&K60) | |||||
| 50um-5000 | H- 1/2″ Hose Barb (K68B only) | |||||
| X -Others ( If you need other connector pls make inquiry) | ||||||
| For Example: PES membrane, 0.2um, 2200cm2 filtration area, 1.5″ Tri-clamp —K68CIPS020A5 | ||||||

Name: K60-2C-M10
Inlet & outlet: 1/4″compression joint:
Filtration area: 450cm²

Name: K68B-4H-M10 2.5″
Inlet & outlet: 1/2″hose barb
Filtration area: 1200cm²

Name: K68C-TC-1H 5″
Inlet & outlet: 1.5″Sanitary flange connector
Filtration area: 2200cm²

Name: K68B-2N-M10 2.5″
Inlet & outlet: 1/4″NPT connector
Filtration area: 1200cm²

Name: K68C-MT-1H 2.5″
Inlet & outlet: 1/2″Sanitary flange connector
Filtration area: 1200cm²

Name: K68C-TC-1H 2.5″
Inlet & outlet: 1.5″Sanitary flange connector
Filtration area: 1200cm²To regularly increase the management program by virtue of your rule of “sincerely, good faith and quality are the base of business development”, we extensively absorb the essence of associated solutions internationally, and continuously create new solutions to satisfy the demands of customers for 0.2 um PES membrane biological agent filtration process lab use 2.5″ capsule filter , We have now confident that we can easily offer the premium quality products and solutions at resonable price, good after-sales services into the buyers. And we’re going to produce a dazzling future.
OEM China high quality PES capsule filter, We also have good cooperation relationships with many good manufacturers so that we can give almost all of auto parts and after-sales service with high quality standard,lower price level and warmly service to meet demands of customers from different fields and different area.